<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
		>
<channel>
	<title>Comments on: Effect Of Delivery Pipe Diameter Of A Centrifugal Pump Delivery Time, Flow, Height Used For Water?</title>
	<atom:link href="http://www.roliv.com/effect-of-delivery-pipe-diameter-of-a-centrifugal-pump-delivery-time-flow-height-used-for-water.html/feed" rel="self" type="application/rss+xml" />
	<link>http://www.roliv.com/effect-of-delivery-pipe-diameter-of-a-centrifugal-pump-delivery-time-flow-height-used-for-water.html</link>
	<description>Jobs Salary Internship Colleges Careers Syllabus Notes</description>
	<lastBuildDate>Sat, 30 Jan 2010 06:39:26 +0000</lastBuildDate>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.2.1</generator>
	<item>
		<title>By: oil field trash</title>
		<link>http://www.roliv.com/effect-of-delivery-pipe-diameter-of-a-centrifugal-pump-delivery-time-flow-height-used-for-water.html/comment-page-1#comment-612</link>
		<dc:creator>oil field trash</dc:creator>
		<pubDate>Thu, 28 Jan 2010 22:52:17 +0000</pubDate>
		<guid isPermaLink="false">http://www.roliv.com/effect-of-delivery-pipe-diameter-of-a-centrifugal-pump-delivery-time-flow-height-used-for-water.html#comment-612</guid>
		<description>Turbine Controls
Gas &amp; Steam Turbine Control Systems Design, Manufacure &amp; Installation</description>
		<content:encoded><![CDATA[<p>Turbine Controls<br />
Gas &#038; Steam Turbine Control Systems Design, Manufacure &#038; Installation</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Rajib D</title>
		<link>http://www.roliv.com/effect-of-delivery-pipe-diameter-of-a-centrifugal-pump-delivery-time-flow-height-used-for-water.html/comment-page-1#comment-611</link>
		<dc:creator>Rajib D</dc:creator>
		<pubDate>Thu, 28 Jan 2010 22:46:07 +0000</pubDate>
		<guid isPermaLink="false">http://www.roliv.com/effect-of-delivery-pipe-diameter-of-a-centrifugal-pump-delivery-time-flow-height-used-for-water.html#comment-611</guid>
		<description>Any time you increase the diameter of a pipe on the discharge of a centrifugal pump you reduce the amount of friction loss and the total head the pump must pump against. With lower head the pump will then pump at a higher rate.
The degree to which this change will improve the pumping time is dependent on the length of the replaced pipe, the flow rate from the pump and the pump performance curve. If you have this information then you can estimate the improvement in pumping time.</description>
		<content:encoded><![CDATA[<p>Any time you increase the diameter of a pipe on the discharge of a centrifugal pump you reduce the amount of friction loss and the total head the pump must pump against. With lower head the pump will then pump at a higher rate.<br />
The degree to which this change will improve the pumping time is dependent on the length of the replaced pipe, the flow rate from the pump and the pump performance curve. If you have this information then you can estimate the improvement in pumping time.</p>
]]></content:encoded>